Please complete the form below to request Graham software on CD.
Choose our Vacworks II Selection Software Suite or SealCool Software.
Vacworks II Selection Software Suite
Vacworks II is a selection software suite developed by Graham engineers that enables you to select ejector systems or ejectors in combination with liquid ring vacuum pumps. You are able to select up to a four-stage ejector system, with or without a precondenser, that includes either surface type or direct contact inter and after condensers. The software will provide you with utility consumption, equipment size, and drawings of the individual components. It also includes useful tools for estimating vapor pressures of different organic or inorganic compounds, calculating hydraulic losses in piping systems under vacuum, determining the proper tail leg height for a vacuum condenser, a calculation routine for converting between mass and volumetric flow rate, and a conversion utility for converting between different units of measure.
Design Curve Calculations for Sample. 'Simple Ejector Design Parameters,' by P. Mar 23, 2012 - of a compressible fluid ejector used in particular in sugar refineries for. Conditioning, and in a complementary study 6 they investigated an ejector design using a. Ejector Design Calculation Software. 7/16/2017 0 Comments PTC: Enhancement Details. PTC Windchill 1. 20 What's New PDF on Reference Documents Site.
Vacworks Software:
Vacuum and Heat Transfer Technical Articles
Multimedia Presentation
SealCool Software
Our SealCool software assists in sizing our Heliflow Heat Exchangers.
In this article, we will see the Ejector Working Principle
An ejector is a device used to suck the gas or vapour from the desired vessel or system. An ejector is similar to a vacuum pump or compressor. The major difference between the ejector and vacuum pump or compressor is it had no moving parts. Hence it is relatively low-cost and easy to operate and maintenance-free equipment.
The operating principle of the ejector is the pressure energy in the motive fluid is converted to velocity energy by an adiabatic expansion in the Converging/Diverging
The operating principle of the ejector is the pressure energy in the motive fluid is converted to velocity energy by an adiabatic expansion in the Converging/Diverging Nozzle. Due to the pressure drop of the motive fluid, it will create a low-pressure zone before the mixing chamber. Due to the low-pressure zone, the suction fluid will start to move toward it and mix with motive fluid in the mixing chamber. In mixed fluid enter the diverging portion of the ejector where its velocity energy is converted into pressure energy.
The suction line of the ejector is connected to the vessel which is to the kept under low pressure. Refer to the below figure, a high pressure motivating fluid enters at “A” and expands through the converging-diverging nozzle to “B”. The motive fluid will create a vacuum in the mixing chamber refer to to the pressure curve where the pressure is decreased and velocity is increased. Due to this suction fluid “C” (air or gas) from the connected vessel moves toward the mixing chamber “D”. When the suction fluid starts to mix with the motive fluid in the mixing chamber. The velocity of the fluid at the mixing chamber is approximately 600 to 900 meters per second.
Then the mixture travels through the diffuser “E”, its velocity energy is converted into pressure energy. Thereby the mixture gained higher pressure send to the atmosphere or some closed system. Normally the discharge pressure will be 10 to 15 times of the suction pressure
The capacity of an ejector is determined by its dimensions. By the required capacity is very high then two or three ejectors are working in parallel. if greater compression is required, two or more ejectors will be arranged in series.
Ejectors may be installed at any orientation. However, it is very important to provide a provision to remove the condensate or solid particles from the entrained gases of an ejector. Since any condensed or solid particles may reduce the throughput capacity of the ejectors.
Hence it very important to provide a drain valve installed at low points can be either manual or automatic float operated valves.
Another important thing to check during ejector installation is external loads(Piping load) act on the ejectors. Since any misalignment will adversely affect the performance of ejector.